User Tools

Site Tools


errors

This is an old revision of the document!


Errors

Here is the list of errors that can be emitted by 10LC, along with additional details about each one.

Parser Errors

All parser error numbers start with a “P”. This list is not exhaustive, and since different parser error codes may be emitted with the same underlying error message, this list will only list the messages.

Text Details
Byte values must be between 0x00000000 and 0x000000FF (0 and 255) An value was specified that was expected to be within the range of a byte, but exceeded that range.
Syntax error, expected: ; The line in question or the line above it is missing the statement terminator, which is a semicolon, or an invalid character was present in a label or program name.
Syntax error, expected: DisplayString The Display statement expects a quoted string but something else was provided instead.
Strings used in Display and Serial statements cannot be longer than 32
printed characters
The Display and Serial statements in 10LC limit the string to 32 printed characters.
Invalid character: ' " ' If this error is shown at the start of the quoted string for a Display or Serial statement, it actually means the quoted string contains at least one unsupported character.
Syntax error, expected: RegName, Symbol, IntegerValue, Not, And, Or,
ShiftL, ShiftR, Increment, Decrement, Goto
This usually means that an unexpected comparison operator or symbol was encountered in an If expression.
Syntax error, expected: SetupBeep, SetupInteractiveErrors,
SetupEnableFL, SetupLineSize, SetupNewline, SetupPod,
SetupXOn, SetupXOff, SetupPodTimeout, SetupTraps,
Program, EndProgram, Read, Write, WriteCtrl, Learn,
Alias, Const, Global, RegName, Symbol, Increment,
Decrement, Execute, SetupMemMap, Display, AutoTest, BusTest,
LongRAMTest, ShortRAMTest, ROMTest, IOTest, Not, Ramp, Walk,
ToggleAddress,
ReadProbe, ReadTape, WriteTape, ToggleData, ToggleCtrl,
ReadStatus, Stop, RunUUT, LabelMarker, Goto, If, Sync, Setup,
Delay, Fill, FillRamp, Serial, ShiftL, ShiftR, CompilerDirective, Equals, AndEquals, OrEquals, ShiftLEquals, ShiftREquals
This is a long error saying that you likely doubled a semicolon somewhere or used a keyword/statement that does not exist in 10LC.
Syntax error, expected: Repeat, Loop, ;, Into A statement has an unsupported value in it.

Compiler Errors

Error Text Details
L1024 ICE: Unable to find handler for <exp> This is an Internal Compiler Error that should not occur - contact me if it does.
L1025 ICE: Pod name <name> is unknown This is an Internal Compiler Error that should not occur - contact me if it does.
L1026 ICE: Unexpected operator type <optype> encountered for {symbol} This is an Internal Compiler Error that should not occur - contact me if it does.
L1027 ICE: Unexpected IF operator type {optype} encountered This is an Internal Compiler Error that should not occur - contact me if it does.
L1028 ICE: No value obtained for resolved Const This is an Internal Compiler Error that should not occur - contact me if it does.
L1029 ICE: Unexpected IF modifier type {modtype} encountered This is an Internal Compiler Error that should not occur - contact me if it does.
L1030 ICE: No register obtained for resolved Alias This is an Internal Compiler Error that should not occur - contact me if it does.
L1512 <value> was unexpected, expected a Register or an Alias A value was specified where a register (or an alias) was expected.
L1513 <name> was unexpected, expected a Value or Const A register or alias was specified where a value (or constant) was expected.
L1514 <something> was unexpected, expected a Value, Const, Register, Alias or an Expression An unrecognized symbol was specified where a value, constant, register, alias or expression was expected.
L1515 <something> was unexpected, expected a Value, Const, Register, or an Alias An unrecognized symbol was specified where a value, constant, register, or alias was expected.
L1516 <something> was unexpected, expected an Expression An unrecognized symbol was specified where an expression.
L1517 The Loop option can only be specified once on a statement The Loop execution option can only be specified once on a statement.
L1518 The Loop option can only be specified as the last option on a statement (after any Repeat options) The Loop execution option can only be specified as the last or only option on a statement.
L1519 <value> was unexpected as the INTO value; expected a Register or an Alias You must specify a Register or an Alias with the INTO version of the Read statement.
L1520 The symbol <symbol> is unknown and could not be identified as a Constant or an Alias You have specified a symbol that cannot be found in any of the global or local symbol tables.
L1521 The <statement> statement can only be used inside the context of a Program In 10LC, certain statements can only be used inside of a Program. This is one of them.
L1522 The <statement> statement can only be used outside the context of a Program In 10LC, certain statements can only be used outside of a Program. This is one of them. (If getting this with a Program statement, did you forget an EndProgram statement?)
L1523 A Program named <name> has already been created or referenced A program with the same specified name already exists.
L1524 A Program with number <number> (“<name>”) has already been created or referenced A program with the same specified number already exists.
L1525 The specified program number is out of range - it must be between 0 and 99 Program numbers on the 9010A between 9 and 99 (in decimal).
L1526 The specified label <label> already exists as label number <number> You created a label using a name or number that has already been used by another Label in the program.
L1527 An Alias named <name> has already been created A local Alias already exists with the same specified name.
L1528 An Constant named <name> has already been created A local Constant already exists with the same specified name.
L1529 An Global Constant named <name> has already been created A global Constant already exists with the same specified name.
L1530 The display string must be no longer than 32 printable characters In 10LC the strings used with the Display statement have a printable limit of 32 characters.
L1531 A shift count of <value> is invalid; expected a value from 1 to 32 With shift operations, you can only specify a shift count between 1 and 32.
L1532 <value> was unexpected as a bit count; expected a Value or an Constant The specified value cannot be used to indicate a bit count.
L1533 Forcing line name <name> was not understood - are you using the correct Pod? You have specified a Forcing Line name that was not found in the configuration of the selected Pod.
L1534 Forcing line number <number> was not understood - are you using the correct Pod? You have specified a Forcing Line number that was not found in the configuration of the selected Pod.
L1535 Only one {modifier} statement is allowed. You can only specify the indicated modifier once.
L1536 If specified, the SetupPod statement must be the first statement in a 10LC file Since Pod configuration affects other setup information, if you are going to specify a Pod, it must be the first statement present.
L1537 <symbol> is not a valid compiler directive You have specified something that was not recognized as a valid compiler directive.
L1538 Program <name> contains a reference to label <name> which was never defined The specified Program referenced the specified Label (via a Goto statement) but never defined that label.
L1539 Compilation stopped because the WarningsAreErrors option is set and a warning was emitted A warning was generated but since the WarningsAreErrors option was set, this stops compilation.
L1540 The extended statements are unavailable because the EnableIntrinsicStatements option was not set The EnableIntrinsicStatements option must be set in order to use the extended/intrinsic statements.
L1541 The SetupPod statement has already been specified (possibly in another file) The SetupPod statement can only be specified once.
L1542 The SetupBeep statement has already been specified (possibly in another file) The SetupBeep statement can only be specified once.
L1543 The SetupInteractiveErrors statement has already been specified (possibly in another file) The SetupInteractiveErrors statement can only be specified once.
L1544 The SetupBusTestAddress statement has already been specified (possibly in another file) The SetupBusTestAddress statement can only be specified once.
L1545 The SetupRunUUTAddress statement has already been specified (possibly in another file) The SetupRunUUTAddress statement can only be specified once.
L1546 The SetupXOn statement has already been specified (possibly in another file) The SetupXOn statement can only be specified once.
L1547 The SetupXOff statement has already been specified (possibly in another file) The SetupXOff statement can only be specified once.
L1548 The SetupLineSize statement has already been specified (possibly in another file) The SetupLineSize statement can only be specified once.
L1549 The SetupPodTimeout statement has already been specified (possibly in another file) The SetupPodTimeout statement can only be specified once.
L1550 The SetupNewline statement has already been specified (possibly in another file) The SetupNewline statement can only be specified once.
L1551 The SetupMaskFLMayBeEnabled statement has already been specified (possibly in another file) The SetupMaskFLMayBeEnabled statement can only be specified once.
L1552 The SetupForcingLineNames statement has already been specified (possibly in another file) The SetupForcingLineNames statement can only be specified once.
L1554 A Global Alias named <name> has already been created A global Alias already exists with the same specified name.
L1555 A Program cannot execute itself A Program has an Execute statement that references itself and recursive calls are not supported on the 9010A.
L1556 An unescaped <char> character is followed by <symbol> which was identified as a const value, not a valid register name or Alias. A Program has specified a Constant after a special character that expects a Register identifier.
L1557 An unescaped <char> character is followed by <symbol> which was not identified as a valid register name or Alias. A Program has specified an unknown symbol after a special character that expects a Register identifier.
L1558 There is a limit of 16 Labels per Program A Program can only have 16 labels defined.
L1559 There is a limit of 100 Programs Only 100 Programs can be created on the 9010A.
L1560 Invalid program number <num> specified - program numbers have a range of 0 to 99. A Program declaration specified a Program Number but the specified number was out of range.
L1561 An unescaped <char> character is followed by whitespace instead of a valid register name or Alias. An unescaped <char> character is followed by whitespace where a Register identifier was expected.
errors.1582757436.txt.gz · Last modified: 2020/02/26 16:50 by jtwine